The Mitsubishi Chemical Corporation MCI-Gel® ion chromatography columns are based on functionalized cation and anion exchange resins specially designed for Non-Suppressed Ion Chromatography applications. Non-Suppressed Ion Chromatography is facilitated by the combination of a column based on low-capacity ion exchange resin and an eluent with low electrolyte concentration.
- The MCI-Gel® SCK01 Cation chromatography column is based on a crosslinked polystyrene resin functionalized with sulfonic acid. The SCK01 columns are available in two sizes, 6x50mm and 4.6x150mm, providing excellent resolution and fast analysis of monovalent and divalent cations. Standard monovalent ions like Li+, Na+, NH4+, K+, Rb+, Cs+ and simple amines such as mono-, di-, and trimethylamine can be resolved using a nitric acid solution as eluent. Divalent cations, such as alkaline earth metals and transition metal elements, can be efficiently resolved using tartaric acid and a complexing agent such as ethylen diamine to selectively elute the metals from the column. When using the SCK01 column for monovalent ions it is advised to use the SCK-PC pre-column to trap any possible heavy metals in order to avoid losing capacity and chromatographic performance. Check the PDF below for sample chromatograms.
- The MCI-Gel® SCA04 Anion chromatography column is based on a hydrophilic 5µm particle size polyhydroxymethacrylate resin functionalized with quaternary ammonium groups. The SCA04 is a PEEK column (6x150mm). A solution of potassium hydrogen phtalate and a vanilic acid (VA)/N-Methyldiethanolamine (MDEA) can be used as an eluent. The VA/MDEA eluent is specifically developed for the SCA04 column enabling the analysis of 7 standard anions in 14 minutes without any system peak. To extend the column life it is advised to use the SCA-PC pre-column between the eluent pump and the injector.
Columns
Art.Nr. | Column Name | Dimensions ID x L | Column Material | Resin – particle size | Analysis |
---|---|---|---|---|---|
0034-01 | MCI-Gel SCK01 | 6mm x 50mm | Stainless Steel | ST/DVB – 11µm | Cations |
0034-04 | MCI-Gel SCK01 | 4.6mm x 150mm | Stainless Steel | ST/DVB – 11µm | Cations |
0034-21 | SCK-PC pre column | 6mm x 50mm | Stainless Steel | ST/DVB – 11µm | Cations |
0133-02 | MCI-Gel SCA04 | 6mm x 150mm | PEEK | HMA – 5µm | Anions |
013312 | SCA04G guard column | 4.6mm x 30mm | PEEK | HMA – 5µm | Anions |
0130-22 | SCA-PC | 8mm x 10mm | Stainless Steel | – | Anions |
- Have a look at our Sykam ion-chromatography systems here.